This applies to the cmd() and cmd_prompted() methods and determines whether these methods should return the success or failure of the issued command (i.e. The first calling sequence returns the cmd error message associated with the object. Polling method (only applicable in non-blocking mode): This method connects to the host device. Use of either of these SSH authentication methods (which both ultimately provide username & password credentials to the SSH server) remains completely transparent to the code using this class. If the reset_prompt flag is set any prompt supplied via the argument will be ignored. All CLI commands cache changes. Note also that this functionality is only available if the host is detected as an Extreme Networking product, i.e. If instead an error message was generated by the host, then the command is deemed unsuccesful and the result is false (0). 1 ACCEPTED SOLUTION Drew_C Valued Contributor III Options 11-16-2015 05:12 PM Based on some of the comments in this thread and on the "EXOS Cheat Sheet," we've published an EXOS Quick Guide that explains a lot of the basics. ExtremeCloud IQ manages the time-out and terminates any SSH sessions upon time-out. base_mac: Base MAC address of the device in string format xx-xx-xx-xx-xx-xx. When that happens the cmd method will timeout and the error mode action is performed. By default the object console is undefined, and automatically updates itself to true when connecting via Serial, or Telnet (with port other than 23) or SSH (with port other than 22). In this blog, I focus on using troubleshooting with CLI from the cloud. The outbound ports that need to open on remote customer firewalls are 20000 - 20255 and 22. Figure 1 An admin selects a managed network device in ExtremeCloud IQ for the creation and management of an end-to-end SSH tunnel. Extreme - How to collect a show tech or a tech-support on Extreme unit_number: Unit number we are connected to (Generaly the master unit, except when connecting via Serial) if a stack; undef otherwise, master_unit: Master unit number, if a stack; undef otherwise. See attribute(). You can access the CLI by using: A terminal emulation program running on a computer connected to the serial port on the device (AP, wireless controller, and service platform). They promote the advances and the momentum of the worlds most exciting networking company through best-in-class events and communications. PassportERS family_type) you can append '-y' to the command being sent to suppress the Y/N confirmation prompt, in which case you can simply do: However, other Extreme Networking devices do not accept a '-y' appended to the reset/boot commands (e.g. Once a connection is established (including login) the family_type attribute is always set. Extreme Networks ExtremeRouting SLX 9640 - router - CDW channelized ports 1/2/1-1/2/4 will be seen as ports 2/1,2/2,2/3,2/4 on the port list for slot 1. The ap: context is the highest-level context for AP configuration. See http://dev.perl.org/licenses/ for more information. Figure 5. My question is what if I don't have anything else acting as a router on my network (we're a pretty small setup)? Attributes which only apply to HiveOS family type: is_hiveos: Flag; true(1) if the device is a HiveOS Cloud AP; false(0) otherwise. In this case the XOS switch will not request a login until the user has hit a key; setting this method to 1 (or setting the Console argument to 1 in the object constructor) will ensure that the XOS banner is acknowledged and the login will not time-out. This is the constructor for Control::CLI::Extreme objects. BaystackERS: 9600, 19200, 38400 or 'max' (where 'max' = 38400), PassportERS: 9600, 19200, 38400, 57600, 115200 or 'max' (where 'max' = 115200). To prevent the object console mode from auto updating following connection, you may set it with this method to a defined false value (0); this will result in wake_console being permanently disabled. The "prompt_credentials" argument is provided to override the global setting of the parameter by the same name which is by default false. ExtremeXOS/Switch Engine CLI commands ExtremeXOS/Switch Engine CLI commands can be combined into a script to execute in sequence using Type=CLI. On these devices this attribute will return a defined value. As shown in Figure 2, ExtremeCloud IQ queries the cloud SSH proxy servers to get an available port, generate credentials, and create a user. Attributes which only apply to Series200 family type: unit_number: Unit number we are connected to (always the stack manager unit) if a stack; undef otherwise, manager_unit: Stack Manager unit number, if a stack; undef otherwise, stp_mode: Spanning tree operational mode; possible values: stpg (802.1D), rstp (802.1W), mstp (802.1S), pvst, rpvst. While if the last prompt was in the form 'switch/config/ip#' this method will return '/config/ip'. With this method it is possible to enable cmd() - and cmd_prompted() - to print activity dots (.) as input data is read from the host device. The following example illustrates: If you do not care to retrieve any output from the command: If you want to retrieve the command output sequence along the way: If you only want to retrieve the command output at the end: This method is identical to cmd() except that it will not automaticaly feed a 'y' to Y/N confirmation prompts but in a more general manner will detect any prompts generated by the issued CLI command (whether these are Y/N confirmation prompts or simply prompts for additional information the CLI command requires) and will feed whatever data has been provided to the method. In non-blocking mode (blocking disabled), the device_peer_cpu() method will most likely immediately return with a false, but defined, value of 0. The second calling sequence sets the cmd error message for the object. FN-2023-488-Default Certificates in XIQ Expired - Extreme Networks - 96220 In non-blocking mode, the poll status will most likely immediately return with a false, but defined, value of 0. Ability to detect whether a CLI command generated an error on the remote host and ability to report success or failure of the issued command as well as the error message details. See errmode(). Some commands are common to all AP contexts and some apply only to specific AP contexts. is_apls: Flag; true(1) if an Extreme Product Label Switch (APLS); false(0) otherwise. Speak to Us About Creating Your Infinite Enterprise, CLI Troubleshooting Commands for the Cloud. Whereas the "timeout" argument is the normal timeout used for reading the connection once established; this is fed to login(). Available in 24 and 48-port gigabit and multi-gigabit models, the 5720 is a universal hardware platform, providing end-to-end secure network segmentation and advanced policy capabilities. The latter two generally represent connection to some terminal server deivce. apls_box_type: Box Type of an Extreme Product Label Switch (APLS); only set if is_apls is true, undefined otherwise. Arguments after $ok will only be defined if $ok is true(1). On subsequent calls, the arguments provided are ignored and the method simply polls the progress of the current task. For a serial connection, this method - or to be precise the login() method which is called by connect() - will automatically send the wake_console string sequence to the attached device to alert it of the connection. It should not normally be necessary to provide username/password since the credentials used to connect to the current CPU will automatically be used. The following example illustrates: Changing host and serial port together (backward compatible syntax): Changing host and serial port together (new syntax for non-blocking use): This method is only applicable to an already established Serial port connection and will return an error if the connection type is Telnet or SSH or if the object type is for Serial but no connection is yet established. By default this functionality is disabled. ExtremeCloud IQ does not participate in the conversations during the SSH session and has no knowledge of the content inside the SSH tunnel. Once set, these patterns are only used by the cmd() and cmd_prompted() methods. See wake_console(). The command-line interface (CLI) is a text-based way to manage and monitor the system. When connecting to the serial console port of a device it is necessary to send some characters to trigger the device at the other end to respond. In non-blocking mode (blocking disabled) the connect() method will immediately return with a false, but defined, value of 0. The default prompt match pattern used is: The first form of this method allows reading the current setting; the latter will set the new Y/N prompt and return the previous setting. These should be called using their fully qualified package name or else they can be expressly imported when loading this module: Please report any bugs or feature requests to bug-control-cli-extreme at rt.cpan.org, or through the web interface at http://rt.cpan.org/NoAuth/ReportBug.html?Queue=Control-CLI-Extreme. Note that this module is in no way supported or endorsed by Extreme Inc. You can find documentation for this module with the perldoc command. If a CLI command is found to generate a prompt for additional data - i.e. switch# ls ? Note that if no debug_file is defined all debug messages will be printed to STDOUT. These commands are found within the users context of the CLI. VOSS VSP hosts can be configured for either 'password' or 'keyboard-interactive' authentication. Extreme Networks - 16568 - Extreme Networks 210-24t-GE2 Ethernet Switch - 24 x Gigabit Ethernet Network, 2 x Gigabit Be the first to review this product. In non-blocking mode (blocking disabled), the enable() method will most likely immediately return with a false, but defined, value of 0. Trusted by more than half of the Fortune 50, Extreme is a market leader in cloud networking. In an earlier blog, I discussed the power of CLI configuration in the cloud. If the device was not in config mode at the last prompt, this method returns an empty string ''. In the syntax layout below, square brackets [] represent optional parameters. An example follows: If using the login() method in non-blocking mode, the following examples illustrate how this works: If you do not care to retrieve the login sequence output: If you want to retrieve the login output sequence along the way (even in case of error/timeout): If you only want to retrieve the full login sequence output at the end: This method sends a CLI command to the host and returns once a new CLI prompt is received from the host. With its versatile design, the ExtremeSwitching X670-G2 provides high density Layer 2/3 10Gb networking with low latency cut-through switching, and IPv4 and IPv6 unicast and multicast routing. If instead return_result is not set then this method will return either a hard reference to the output generated by the CLI command or the output itself. All CLI commands cache changes. max_baud: Maximum configurable value of baudrate on device's console port. Attributes which only apply to SLX family type: is_slx: Flag; true(1) if the device is an SLX switch. The 5720 Series is a family of high-performance, feature-rich edge and aggregation switches designed for the next-generation digital enterprise. I will collect and update this table as many as possible. Returns the configuration context included in the last prompt received from the host device. is_master_cpu: Flag; true(1) if connected to a Master CPU; false(0) otherwise, is_dual_cpu: Flag; true(1) if 2 CPUs are present in the chassis; false(0) otherwise, cpu_slot: Slot number of the CPU we are connected to, is_ha: Flag; true(1) if HA-mode is enabled; false(0) otherwise; undef if not applicable, stp_mode: Spanning tree operational mode; possible values: stpg (802.1D), rstp (802.1W), mstp (802.1S), oob_ip: Out-of-band IP address of Master CPU (this attribute is only set when connected to the Master CPU), oob_virt_ip: Out-of-band Virtual IP address (this attribute is only set when connected to the Master CPU), oob_standby_ip: Out-of-band IP address of Standby CPU (this attribute is only set when connected to the Master CPU), is_oob_connected: Flag; true(1) if the connection to the device is to either the oob_ip or oob_virt_ip IP address; false(0) otherwise (this attribute is only set when connected to the Master CPU; it will be undefined if connected to a Standby CPU). This method overrides Control::CLI::connect() and calls both the Control::CLI::connect() method as well as the login() method from this class. See prompt_credentials(). So even if the CLI prompt is changed by the issued command (e.g. Feel free to check out their product line at http://www.extremenetworks.com/. Note that this method is automatically invoked by the connect() method and therefore should seldom need to be invoked by itself. Note that for best script performance it is recommended to disable more paging on the host device using the appropriate CLI command or the device_more_paging() method. If password authentication fails for any reason the error mode action is performed. Furthermore the prompt string is automatically internally set to match the actual prompt of the connected device (rather than using a generic regular expression such as '*[#>]$'). To do enable routing on the interface level, use the following commands from global config (the commands below use interface 1/0/1 as an example, fill in your own interface as needed: Now that routing is enabled for that interface, the command to create a static route would be: ip route
What Triggers A California Residency Audit,
Manhattan Post Obituaries,
Sunshine Family Farms,
Articles E